Installing the Stove
Continue adding vent
components, locking each
succeeding component into
place.
3. Install Support Brackets
For Horizontal Runs - The vent system must be
supported every 5 feet (1.5m) of horizontal run by a
horizontal pipe support.
To install support brackets for
horizontal runs:
• Place the pipe supports
around the vent pipe.
• Nail the pipe supports to the
framing members.
For Vertical Runs - The vent
system must be supported
every 8 feet (2.4m) above the
stove vent outlet by wall
brackets.
To install support brackets for
vertical runs:
• Attach wall brackets to the
vent pipe and secure the
wall bracket to the framing
members with nails or
screws.
(continued)
Figure 12. Adding
Venting Components
1 INCH MIN.
(25.4mm)
D'ÉCHAPPEMENT)
Figure 13. Installing
Support Brackets
Installation
Figure 12.
Ajout de sections
3. Pose des supports de montage
Sections horizontales - Le système de ventilation doit
être soutenu par un support horizontal tous les 1,5 m (5
ft) de conduit horizontal.
WALL
BRACKET
(SUPPORT MURAL)
WALL STUD
(MONTANT DU MUR)
8 ft
(2.4mm)
VENT OUTLET
(ORIFICE
Figure 13.
Pose des supports de montage
26
(suite)
Continuer à ajouter des
sections et à les verrouiller
successivement.
Pour poser des supports de
conduit horizontal:
• Placer les supports autour
du conduit.
• Clouer les supports dans
les
montants
charpente.
Sections verticales - Le
système de ventilation doit
être
soutenu
supports accrochés aux
murs tous les 2,4 m (8 ft) au-
dessus
de
d'échappement de l'appareil
de chauffage.
Pour poser les supports de
conduit vertical:
• Attacher les supports
muraux sur le conduit et
les clouer ou visser sur les
montants de la charpente.
de
la
par
des
l'orifice