TECHNICAL DATA
Parameter description
Parameter Value
Product name
Temperature &
Humidity Data Logger
Model
SBS-DL-123
SBS-DL-123L
Battery type
Lithium 3,6V
2 x 1,5V AAA
Temperature
-35 ÷ 80
measurement range
[°C]
Accuracy of
± 0,3
temperature
measurement [%]
Humidity measurement
0-100
range [%]
Accuracy of humidity
± 3
measurement [%]
IP protection class
IP64
Memory size of
32000
readings
Sampling time
2 [s] ÷ 24 [h]
Dimensions
23x37x123
H x W x D [mm]
EN
Weight [kg]
0,048
1. GENERAL DESCRIPTION
The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines,
using
state-of-the-art
technologies
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD
THIS USER MANUAL.
To increase the product life of the device and to ensure
a trouble-free operation, use it in accordance with this user
manual and regularly perform the maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement. Taking
into account technological progress and noise reduction
opportunities, the device was designed to reduce noise
emission risks to the minimum.
Legend
The product satisfies the relevant safety
standards.
Read the instructions before use.
The product must be recycled.
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual machine.
U S E R M A N U A L
The original operation manual is in German. Other language
versions are translations from German.
2. Use guidelines
The temperature and humidity data logger is a device
designed to perform measurements of temperature and air
humidity.
The user is liable for any damage resulting from non-
intended uses of the device!

2.1 Device description

-30 ÷ 70
SBS-DL-123
± 0,5
1
5
2
1.
Button
2.
Diode
4
3.
USB plug
4.
USB cover
3
IP54
5.
Diode
SBS-DL-123L
1
25x75x120
0,13
1.
Display
2.
On/Off button |of unit
3 2
selection
3.
Start/Stop button | Max/
Min
4
4.
Diode
and
11 12
13 1
1.
Status of memory usage
2
2.
Temperature
measurement unit
10
3
3.
Reading of temperature
value
4
4.
Moisture measurement
9
5
unit
5.
Reading of humidity
value
6.
Hour/Year/Month and
day
8
7
6
7.
USB connection indicator
8.
Battery charge indicator
9.
Alarm symbol for exceeding the limits of humidity
values
10.
Alarm symbol for exceeding the limits of
temperature values
11.
Minimum reading
12.
Maximum reading
13.
Symbol informing about the active mode of data
recording

2.2 Preparing for use

Battery installation
SBS-DL-123
Follow the activities shown in the figures below in order to
install the battery. Insert the battery in accordance with the
markings of the poles.
6
1
2
SBS-DL-123L
Remove the flap located on the back of the device, insert
the batteries according to the markings and drawings on
the device. Close the flap.
Both models of temperature and humidity meters are
adapted for wall mounting.
The model SBS-DL-123 has a mounting bracket included in
the set which should be screwed to the wall, the meter is
mounted in the holder in the pluggable manner.
The model SBS-DL-123L has a hole in the housing
for hanging the meter on a bolt screwed to the wall,
additionally this model has an adjustable support.
Program and controller installation
Hardware requirements: Windows XP / Vista / 7/8 (32bit or
64bit) operating system; USB port; CD-ROM drive.
The user must have administrator rights on a given
computer where the program and driver will be installed.
1.
Place the CD attached to the set in the CD-ROM
drive of the computer.
2.
If the program does not start automatically, it is
necessary to double click on the file „setup.exe"
located in the catalogue CD – > Software directory.
The program installation process will start.
3.
Execute
boxes on the computer screen. After finishing the
installation, the „Data LoggerGraph" program icon
will appear on the desktop.
4.
In order to enable parameter readings from the
meter it is necessary to install the controller also
placed on the attached CD.
5.
In order to install the controller, it is necessary
to double click on the „USBpressInstaller.exe" file
located in the catalogue CD – > Software directory.
6.
Execute the subsequent commands displayed in the
boxes on the computer screen. After finishing the
installation of the controller, information about the
correct installation of the controller should appear
on the screen.

2.3 Device use

SBS-DL-123
The meter is operated with a single button. Data reading is
possible only through the Data LoggerGraph program due
to the lack of display in the device.
After switching on the device, the button has the function
depending on user settings selected in the „Start and Stop
Method" tab of the „Data Logger Setup" window:
„Start by Button – the start of data recording takes
place after pressing and holding the button;
„OverwriteWhen Full / By Button" – stoppage of data
recording after pressing and holding the button.
Rev. 05.06.2018
Rev. 05.06.2018
The above settings are factory settings. In other cases, the
3
device automatically starts/stops recording according to
user settings.
Description of the meaning of the signals displayed by the
4
diodes on the device.
No signals – device in inaction mode; lack of battery
or discharged battery;
One green diode blinking every 10s – data recording;
5
Two green diodes blinking every 10s – data recording
finished
One red diode blinking every 10s – data recording,
alarm on at least one channel;
Two red diodes blinking every 10s – data recording
finished, alarm on at least one channel;
One yellow diode blinking every 60s – poorly
charged battery, data recording is in progress, the
battery must be replaced;
One yellow diode blinking every 1 second – USB
correctly connected
Blinking of yellow and green diode one after
another – message after connecting the meter to the
computer, battery and power supply correct;
Blinking of yellow and red diode one after another –
message after connecting the meter to the computer,
battery mounted, incorrect power supply.
SBS-DL-123L
The meter is operated by two buttons. In the mode of
display only, without data recording, the buttons have the
following functions:
MAX / MIN / START / STOP – a single press shows on
the display a minimum or maximum reading from the
last read values;
C / F / ON / OFF – single press causes the change of
the temperature unit, holding down the button turns
off the display
Note: The meter will display the date and time only after
subsequent
commands
displayed
in
connecting it to the computer and activating the „LOG"
mode. Every break in power supply (removing the battery,
turning off the display) makes it necessary to connect the
meter to the computer again.
In the mode of data recording, the buttons have the
following functions:
MAX / MIN / START / STOP – a single press shows
on the display a minimum or maximum reading
from the last read values. If the user has selected the
„Start by Button" option in the program – pressing
and holding the button causes the start of data
recording (hold down the button until the message
„LOG" (13) appears on the display); in the selected
„OverwriteWhen Full / By Button" option, pressing
and holding the button causes the end of data
recording.
C/F/ON/OFF – the function the same as in the case of
the display mode.
In the case of exceeding the alarm thresholds set in the
program, the device releases the sound signal.
NOTE: In both models, data recording it is only possible
after connecting the device to the computer's USB port. The
devices do not have own internal memory, slots of memory
cards, etc.
7
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sbs-dl-123l

Table des Matières