NOTE:
• If you have activated the switch-off time before-
hand, the appliance automatically finishes ice
cube making.
• If operation is manually interrupted, water which
is no longer needed is fed back to the water tank.
Only then will the appliance stop. Half-finished ice
cubes remain suspended on the cooling rods. As
soon as it is sufficiently thawed, it will fall off and
drop into the ice cube tray.
Indicator Lamp
(Ice cube tray full)
The temperature sensor stops the ice cube production
as soon as the ice cube container is full. The indicator
lamp
lights up and a beep tone sounds.
NOTE:
When removing the ice cube tray, some water will
drip through the holes onto the floor.
WARNING:
• Switch off the device before cleaning and disconnect the mains
plug.
• Never immerse the appliance in water to clean it. Doing so may
lead to electric shock or fire.
CAUTION:
• Do not use wire brushes or other abrasive implements.
• Do not use harsh or abrasive cleaning agents.
• Do not use chemicals, acids, petrol or oil products.
NOTE:
• For hygienic reasons exchange the water in the
tank after 24 hours.
• Remove the ice cube tray after use. If the water
tank remains open no mould or bacteria can form.

Ice Cube Container (6)

Remove the ice cube container and clean it with a mild
detergent under running warm water.
44
PC-EWB1007_IM

Cleaning and Maintenance

• Remove the ice cubes with the supplied ice cube
scoop.
• The indicator lamp
ments later ice cube production starts again.
Indicator Lamp
(Water refill)
The indicator lamp turns on if the water tank is nearly
empty and a beep tone sounds. Ice cube production is
automatically halted.
• Empty the ice cube tray.
• Refill with potable water as described in chapter
"Make ice cubes". Since there may still be water
in the appliance, check the MAX mark in the water
tank.
• Close the ice cube tray.
• Touch ON on the display, to restart ice cube produc-
tion. The indicator lamp

Casing and Interior

• Clean casing and interior with a damp cloth.
• Use a diluted solution of vinegar and water.

Drain Residual Water (4)

Drain the residual water if the appliance is not in use
for a longer period of time. Rest the appliance on a
table edge. Hold a bowl under the residual water drain
valve.
turns off and a few mo-
turns off.