Les langues disponibles

English
Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
lamp
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling
fan.
Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Rechargeable batteries
EB712S, EB7S, EB714S, FEB7S, EB7B, EB912S,
EB9S, EB914S, EB914, FEB9S, EB9B, EB924,
EB1212S, EB12S, EB1214S, EB1214L, FEB12S,
EB12B, EB1220BL, EB1224, EB1412S, EB1414S,
EB1414, EB14B, EB1424, EB1812S, EB1814SL,
EB18B EB1820, EB1820L, EB1824L
EB926H, EB930H, EB933X, EB1226H,
EB1230H, EB1230HL, EB1230X, EB1233X,
EB1426H, EB1430H, EB1430X, EB1433X,
EB1826HL, EB1830H, EB1830HL, EB1830X, EB1833X
BCL1430, EBM1830
10
Table 2
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
(RED)
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light
Flickers
for 0.1 seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
Table 3
Malfunction in the
battery or the charger
Battery
Unable
(Charging will commence
when battery cools).
Temperatures at which
the battery can be recharged
23°F—131°F (–5°C — 55°C)
23°F—122°F (–5°C — 50°C)
32°F—122°F (0°C — 50°C)
overheated.
to
charge