4.2 Ventilation

It is extremely important for the compressor unit is properly ventilated and that the
supply of fresh air is always guaranteed. The product is equipped with a fresh air inlet
and hot air outlet from the single front grille.
Always leave the front ventilation grille free and do not obstruct it with boxes, bags,
etc.
Front View

4.3 Water network connection

WARNING! This appliance must be supplied only with cold water approved
for human consumption (drinking water).
The operating pressure must be between 100 KPa (1 bar) and 600 KPa (6 bar).
The water network connection must be made in accordance with the Manufacturer's
instructions by professionally qualified personnel. The product is supplied with
a new seal for water connection. Use new seals each time the water network is
disconnected/re-connected. Old seals must not be reused.
A tap must be installed between the water network and the product supply tube in
such a way that the passage of water can be interrupted if necessary.