TROUBLESHOOTING
Fault
Motor not running
‡ Weak spraying force
‡ Weak suction force
10
Cause
> Power supply
interrupted
> Spray nozzle clogged
(Fig. 11a)
> Filter in fresh water
tank clogged (Fig. 8b,
9c)
> Fresh water tank
empty
> Pressure pump
defective
> Lid not fitted correctly
on dirty water tank
(air leaks)
> Nozzle clogged
> Suction hose
connections not
correctly fitted (air
leaks)
> Dirty water tank is full,
float switch interrupts
power supply (Fig. 12)
> Air filter clogged
(TW 300 S: Fig. 8c
TW 350: Fig. 9d)
> TW 350 only:
Dirty water drain hose
not closed (Fig. 10b)
Remedy
Check mains lead,
plug socket, fuse
Clean and/or descale
nozzle
Clean
Refill
Call Alto technician or
authorised specialist
Fit lid tightly; check
gasket
Clean
Check
Empty dirty water tank
Clean
Close