14.
Indoor humidity alarm
15.
Indoor humidity
16.
Atmospheric precipitation unit
17.
Outdoor temperature
18.
Outdoor temperature
19.
Outdoor receiving signal
20.
Outdoor humidity
21.
Transmitter battery charge level
22.
Outdoor humidity alarm
23.
Value of atmospheric precipitation
24.
Range of precipitation time (1h, 24h, week, month,
total)
25.
Wind speed
26.
Wind speed units
27.
Wind speed alarm
28.
Time
29.
Button panel (not shown in the illustration):
a)
"SET" button
b)
"+" button
c)
"HISTORY" button
d)
"ALARM" button
e)
"MIN/MAX" button
3.2. PREPARING FOR USE
ASSEMBLING THE DEVICE
Caution: Before installing the weather station in a target
place, configure the set and, afterwards, check if the device
is working properly.
Inserting batteries
1.
Remove the battery compartment cover.
2.
Insert the batteries into the compartment observing
EN
the polarity
3.
Replace the battery compartment cover.
Note: If you need to replace the batteries with new ones,
proceed in the same way as above.
CONFIGURING THE SET
A. Transmitter
1.
After installing the batteries, the transmitter will start
for a short time and this will be indicated by the LED
light. Then the LED will turn off and the transmitter
will go into normal operation mode.
2.
A transmitter will start searching for a radio time
signal. If a signal reception is correct, a diode will
flash and, afterwards, light for several seconds.
3.
When operating in a standard mode, a diode will
light for a moment every 48 sec.
B. Receiver
1.
After the batteries are installed, the receiver will start.
2.
A receiver will start searching for a transmitter signal.
The icon of a radio signal reception will appear on
a display.
3.
When the receiver detects a transmitter signal, it will
switch to a standard operation mode.
4.
When no radio signal is detected, the device restart
searching every 6 hours.
5.
If the signal is lost or the measurement results are
not displayed:
a)
press and hold the [RESET] button on the
transmitter;
b)
take out the batteries and after about 2 minutes
put them back into the battery compartment of
the receiver.
TRANSMITTER INSTALLATION
A. Mounting bracket
1.
Unpack the transmitter components and check their
condition.
2.
Attach a metal flat bar to the bottom of the
transmitter.
3.
Insert the "U" pins into the holes of the flat bar and
secure them with the nuts.
B. Wind speed meter (anemometer)
1.
Mount the measuring cups on the shaft. Secure by
tightening the bolt.
Note: pay attention that the anemometer cups can
move freely. Too tight mount can interfere with
measurement results.
C. Wind direction indicator (anemoscope)
1.
Mount the weathercock on the shaft by sliding it all
the way to the opposite side of the anemometer and
secure it by tightening the bolt.
Note: make sure that the weathercock can move
freely.
D. Outdoor installation
10
1.
Place the transmitter in its final location using the
mounting bracket (post ø = 1 "÷ 2" not included in
the set).
2.
When installing a transmitter in a target place,
take account for a north direction and install the
transmitter according to the direction which is
marked on a transmitter surface.
3.
Level the transmitter using a level which is placed on
its surface.
Caution: Poor levelling of the transmitter may disturb
measurement results.
RECEIVER INSTALLATION
1.
It is recommended to install a receiver on a flat,
vertical surface to provide a proper transmitter signal
reception.
Caution: a distance from a transmitter, the
appearance of barriers (e.g. walls), electromagnetic
and radio waves may reduce the power of a signal.
3.3. DEVICE USE
3.3.1 SETTINGS MODE
1.
Press the "SET" button for 2s to enter the settings
mode.
2.
Press the "SET" button to enter the desired settings.
•
Time zone (-12> 12)
•
Day format (12h / 24h)
•
Time value (hours/minutes)
•
Day / month format (DD-MM / MM-DD)
•
Calendar
•
Wind speed measuring units (km/h, m/s, bft,
mph, knots)
•
Wind direction
•
Precipitation measurement units (mm / inches)
• Temperature measuring units (° C/ ° F)
3.
Press the "+" or "MIN/MAX" button to modify a value.
4.
Press the "HISTORY" button to exit the setting mode.
3.3.2 CALIBRATION MODE
1.
Press and hold the "HISTORY" button for 8s to enter
the calibration mode.
2.
Press the "SET" button enter the desired settings.
•
Wind speed (0.75-1.25)
•
Precipitation (0.75-1.25)
•
History of precipitation
•
External humidity
•
Outdoor temperature
•
Internal humidity
•
Internal temperature
3.
Press the "+" or "MIN/MAX" button to modify
a value.
4.
Press the "HISTORY" button to exit the setting mode.
3.3.3 HISTORY MODE
1.
Press the "HISTORY" button to enter the memory
mode.
2.
Press the "SET" button to go to erasing memory. Press
and hold the "SET" button again to erase the saved
records.
3.
Press the "MIN/MAX" button to select the 3 ~ 24h
recording interval.
4.
Press the "HISTORY" button or stop the operation for
30s in order to return to normal operation.
3.3.4 ALARM MODE
1.
Press the "ALARM" button to enter the high values
alarm setting mode.
•
Time alarm
•
Wind speeds (0-50 m / s)
•
Wind gusts (0-50 m / s)
•
Wind direction
•
1-hour precipitation alarm (0-999,9)
•
24 hour precipitation alarm (0-999,9)
•
External humidity (1% -99%)
•
Outdoor temperature (-40-60 ° C)
•
Air coolness (-40-60 ° C)
•
Dew point (-40-60 ° C)
•
Internal humidity (1% -99%)
•
Internal temperature (0-50 ° C)
2.
Press the "SET" button to select an available alarm.
3.
Press the "ALARM" button again to enter the low
values alarm setting mode.
•
Time alarm ,
•
External humidity (1% -99%)
•
Outdoor temperature (-40-60 ° C)
•
Air coolness (-40-60 ° C)
•
Dew point (-40-60 ° C)
•
Internal humidity (1% -99%)
•
Internal temperature (0-50 ° C)
4.
Press the "+" or "MIN/MAX" button to modify the
value.
5.
Press the "ALARM" button again to enable or disable
the alarm.
6.
Press the "HISTORY" button or stop the operation for
30 seconds in order to return to normal operation.
Please Note: The duration of the alarm is 120
seconds. To mute the activated alarm signal, press
any button.
3.3.5 MIN / MAX REGISTER MODE
The read mode allows checking the recorded measurement
result (specified in item 3.3.4)
1.
Press the "MIN/MAX" button to enter maximum
values reading menu.
2.
Press the "MIN/MAX" button again to enter
minimum values reading menu.
3.
Press the "+" button to go to the next value readings.
4.
Press and hold the "SET" button at the selected value
to reset the reading to the current value.
5.
Press the "HISTORY" button or stop the operation for
30 seconds in order to return to normal operation.
3.3.6 RETURN TO DEFAULT SETTINGS
1.
Press and hold the "+" button for 20s to restore the
device settings.
3.4. CLEANING AND MAINTENANCE
3.4.1 CLEANING THE PRECIPITATION METER
11
EN