11~200
CH 6
201~255
CH 7
0~255
Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates: damp, smoky or particularly
dirty surrounding can cause greater accumulation of dirt on the unit's optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at
least every 30/60 days.
Specifications
LED source: ........................................................................... 177pcs x 5mm RGB LEDs
Power consumption: ............................................................................................ 36W
Power supply: ........................................................................... AC220-240V, 50-60Hz
Fuse ........................................................................................................................... 3A
Control mode: ................................ DMX512, sound mode, auto mode, Master-Slave
Control channel: ................................................................................................... 7 CH
Features:
.................... color changing, strobe, dimmer 0~100%, speed adjustable
Dimensions: ..................................................................................220 x 220 x 325mm
Weight: ................................................................................................................ 2.8kg
IMPORTANT NOTE: Electric products must not be put into household waste.
Please bring them to a recycling centre. Ask your local authorities or your dealer
©Lotronic – 2014
DMX Auto
DMX Sound
Auto DMX/ Sound DMX Speed (Slow--Fast)
about the way to proceed
.