Problem
The compressor operates
continually.
Water flows on the rear plate
of the refrigerator.
Water flows into the refrigera-
tor.
Water flows on the ground.
The temperature in the appli-
ance is too low.
The temperature in the appli-
ance is too high.
Replacing the bulb
If you want to replace the bulb, do these steps:
1.
Break the circuit of the appliance.
2.
Unscrew the lamp cover securing screw.
3.
Unhook the moving part by pressing it as shown in
the figure.
4.
Replace the bulb with one of the same power and
specifically designed for household appliances (the
maximum power is shown on the light bulb cover).
5.
Fix the lamp cover in place.
6.
Screw the lamp cover securing screw.
7.
Reconnect the appliance.
8.
Open the door and check if the light comes on.
Possible cause
The temperature is not set correctly.
The door is not closed correctly.
The door has been opened too fre-
quently.
The product temperature is too high.
The room temperature is too high.
During the automatic defrosting proc-
ess, frost defrosts on the rear plate.
The water outlet is clogged.
Products prevent that water flows into
the water collector.
The melting water outlet does not
flow in the evaporative tray above the
compressor.
The temperature regulator is not set
correctly.
The temperature regulator is not set
correctly.
Set a higher temperature.
Refer to "Closing the door".
Do not keep the door open longer than
necessary.
Let the product temperature decrease
to room temperature before storage.
Decrease the room temperature.
This is correct.
Clean the water outlet.
Make sure that products do not touch
the rear plate.
Attach the melting water outlet to the
evaporative tray.
Set a higher temperature.
Set a lower temperature.
Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to "Installa-
tion".
3.
If necessary, replace the defective door gaskets.
Contact the Service Center.
Solution
15