5604 Line Scan Vision System Specifications
Specification
Operating Temperature (non-circulating air)
Operating Temperature (circulating air)
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
5705 and 5705C Vision System
Specifications
Specification
Operating Temperature (non-circulating air)
Operating Temperature (circulating air)
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
1
The vision system should be mounted with sufficient clearance on allsidesto allow air circulation around and through the cooling posts
on the blackheat sink. If the vision system isnot mounted with sufficient clearance, a fan isrecommended.
2
Additionalcooling from a fan isrecommended for operation above 40°C. For operation up to 50°C, there must be ≥16 CFM of air
moving through the cooling postson the blackheat sink.
3
The vision system should be mounted with sufficient clearance on allsidesto allow air circulation around and through the cooling posts
on the blackheat sink.
4
Additionalcooling from a fan isrecommended for operation above 40°C. For operation up to 50°C, there must be ≥16 CFM of air
moving through the cooling postson the blackheat sink.
0°C to 45°C (32°F to 113°F)
0°C to 50°C (32°F to 122°F)
-30°C to 80°C (-22°F to 176°F)
95%, non-condensing (Operating and Storage)
IP67 (with appropriate lens cover properly installed).
80 G Shock with 150 gram lens attached per IEC 68-2-27.
10 G from 10-500 Hz with 150 gram lens per IEC 68-2-6.
5705/5715
0°C to 45°C (32°F to 113°F)
0°C to 50°C (32°F to 122°F)
-30°C to 80°C (-22°F to 176°F)
95%, non-condensing (Operating and Storage)
IP67 (with appropriate lens cover properly installed).
80 G Shock with 150 gram lens attached per IEC 68-2-27.
10 G from 10-500 Hz with 150 gram lens per IEC 68-2-6.
10
5604/5614
1
2
5705C
3
4