Gallagher 3E4410 M350 M550 M650 Energizer User Manual
Install the earth system at least 10m (33 ) from any power supply earth peg,
underground telephone or power cable. Drive one 2m (6 ) earth stake into
the ground, un l only 5cm (2") remain above the ground.
Note: Poor grounding can cause
interference on telephone lines, radios
and televisions. This can be recognised
by a clicking sound on telephones.
Step 3. Connect the fence
Connect the energizer's red (FENCE)
terminal to the fence using double
insulated cable. Remove 5cm (2") of
plas c coa ng from one end of the
cable. Bend the end of the wire to
form a loop. Unscrew the red (FENCE)
terminal and insert the loop of wire.
Screw the terminal closed, ensuring
the wire is fi rmly clamped. A ach
the other end of the cable to the
fence using a joint clamp.
Step 4. Plug the
energizer
into a power outlet
Check that the light on the front
of the energizer is fl ashing.
Green
To earth
Red
To fence
Light
11