IMG STAGELINE EMA-200 Mode D'emploi page 5

Masquer les pouces Voir aussi pour EMA-200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All operating elements and connections de scribed
can be found on the fold-out page 3.
1 Operating Elements and Connections
1 Power LED
2 Power switch
3 Inputs (XLR jacks, balanced) of channels 1 and 2:
connection of balanced capacitor microphones or
electret microphones designed for a 48 V phantom
power supply
4 Outputs (XLR chassis plugs, balanced) of chan-
nels 1 and 2: connection to balanced microphone
inputs on the audio unit (mixer or amplifier)
5 Mains fuse; replace a blown fuse by one of the
same type only
6 Mains cable to connect 230 V~/50 Hz
2 Applications
The phantom power supply unit EMA-200 supplies the
required voltage to capacitor microphones or electret
microphones designed for a phantom power of 48 V .
Thus, it allows connection of these microphones to
mixers or amplifiers which do not provide any phantom
power. It is possible to connect up to two microphones
to the unit.
3 Safety Notes
This unit corresponds to all relevant directives of the
EU and is therefore marked with
WARNING The unit is supplied with hazardous
mains voltage. Leave servicing to
skilled personnel only. Inexpert han-
dling of the unit may cause an electric
shock hazard.
Please observe the following items in any case:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
G
Do not place any vessels filled with liquid, e. g. drink-
ing glasses, on the unit.
G
Do not operate the unit and immediately disconnect
the plug from the mains socket
1. if there is visible damage to the unit or to the
mains cable,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled per-
sonnel.
G
A damaged mains cable must only be replaced by
skilled personnel.
G
Never pull the mains cable to disconnect the mains
plug from the socket.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
G
For cleaning only use a dry, soft cloth, never use
chemicals or water.
G
No guarantee claims for the unit and no liability for
any resulting personal damage or material damage
will be accepted if the unit is used for other purposes
than originally intended, if it is not correctly con-
nected, operated, or not repaired in an expert way.
G
Important for U.K. Customers!
The wires in this mains lead are coloured in accord -
ance with the following code:
blue = neutral, brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:
1. The wire which is coloured blue must be con-
nected to the terminal in the plug which is marked
with the letter N or coloured black.
2. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a
disposal which is not harmful to the environ-
ment.
4 Setting the Unit into Operation
Up to two capacitor microphones or electret microphones
can be connected to the phantom power supply unit.
The microphones must have a balanced connection.
1) Connect the cables of the microphones to the
MICROPHONE INPUTS (3) of channels 1 and 2.
(The XLR jacks are provided with a latching device.
To release it, press the PUSH lever of the corre-
sponding jack when disconnecting the plug.)
2) Connect the OUTPUTS (4) of channels 1 and 2 to
balanced microphone inputs of the audio unit used
(mixer or amplifier).
3) Connect the plug of the mains cable (6) to a mains
socket (230 V~/50 Hz).
4) Switch on the phantom power supply unit with the
switch POWER (2). With the unit switched on, the
power LED (1) next to the switch lights up. After op-
eration, switch off the unit with the POWER switch.
5 Specifications
Frequency range: . . . . . . . . 20 – 20 000 Hz
Phantom power: . . . . . . . . . 48 V
Power supply:. . . . . . . . . . . 230 V~/50 Hz
Power consumption:. . . . . . 10 VA
Dimensions (W × H × D): . . 180 × 50 × 145 mm
Weight: . . . . . . . . . . . . . . . . 1.2 kg
Subject to technical modification.
GB
(± 2 V)
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

23.2790

Table des Matières