Troubleshooting
Occasionally, a problem is minor and a service call may not be necessary- use this troubleshooting guide for a possible
solution. If the unit continues to operate improperly, call an authorized service depot or our Toll Free Number 1-844-
455-6097 for assistance.
PROBLEM
No power
Cabinet temperature is too
high
Alarm beeping and "HI" is
displayed on the control
panel
Alarm beeping and "LO"
is displayed in the control
panel
Condensation on the cabi-
net and/or doors
POSSIBLE CAUSE
•
A fuse in your home may be
blown or the circuit breaker
tripped
•
Power surge
•
Plug not fully inserted into wall
outlet
•
Temperature is set too high
•
Door is not shut properly or
opened excessively
•
Exhaust vent is obstructed
•
Recently added a large quantity of
warm beverages to the cabinet
•
Recently added a large quantity
of warm bottles or cans to the
cabinet
•
The door is not closed tightly
•
System leak, evaporator fan fail-
ure or compressor fan failure
•
Sensor failure, evaporator tem-
perature is too low
•
High humidity conditions in the
home
•
Door not shut properly or opened
excessively
10
SOLUTIONS
•
Replace fuse or reset circuit
breaker
•
Unplug the beverage centre, wait
a few seconds and then plug it
back in
•
Make sure the 3-prong plug is
fully inserted into the outlet
•
Verify the temperature control
setting, adjust if neccessary
•
Ensure that the door is fully
closed and that the gasket is
sealing against the cabinet. Open
the doors only as needed and for
short periods of time
•
Verify there is nothing blocking
the front mounted exhausting vent
•
Limit the quantity of warm bev-
erages being introduced to the
cabinet at the same time. Attempt
to stagger the load introduction if
possible
•
Limit the quantity of warm items
being introduced to the cabinet
•
Be sure the door is closed tightly
•
Contact a service centre, to stop
the beeping, unplug the unit
•
Contact a service centre, to stop
the beeping, unplug the unit
•
The condensation will subside
once humidity conditions return to
normal
•
Ensure that the door is fully
closed and that the gasket is seal-
ing against the cabinet. Open the
door only as needed and for short
periods of time