Installation

6.1 General installation advice

Note the following prior to installation:
• The lower edge of the "Unibox TQ RTL
vario" must be at least 20 cm above the
finished floor.
• The front edge of the "Unibox TQ RTL
vario" must be level with the finished wall.
Should the wall not have been
finished, take the plaster and tile
thickness into account.
• The opening of the wall box unit must face
downwards.
• The thermostat must not be influenced by
other heat sources.
• Use the enclosed elbow brackets to align
and fix the "Unibox TQ RTL vario".
• There is a blue dot on the wall box unit. A
hole can be drilled at this location in order
to feed through a cable.
• If necessary, use an empty pipe for cable
routing.
NOTICE
Risk of damage due to lubri-
cants!
Seals may be destroyed by greasing
agents or oil.
f Do not use any greasing agents or
oil for the installation.
f Flush any dirt particles or grease
or oil residues out of the pipework
before installing the product.
f When choosing the operating fluid,
up-to-date technological stan-
dards must be taken into account
(e.g. VDI 2035).
102273680-V01.07.2019
1
2
3
4
5
6
7

Illustr. 6: Installation cross section

(1)
Masonry
(2)
"Unibox TQ RTL vario"
(3)
Plaster
(4)
Pipe conduit unit (separate accessory)
(5)
Edge insulating strip (separate acces-
sory)
(6)
Screed
(7)
Protective tube (separate accessory)