7.5 Quick couplings

Connect the evaporator hoses to the condenser unit hoses via quick coupling: first
connect the pair of capillary hose joints by rotating only the nut present on the female
joint. Connect the second pair of joints remembering to rotate only the nut on the
female joint. Do not dispose of the protective covers. If you need to re-position the
system, connections can be reopened without leakage of refrigerant. In this case,
immediately screw on protective covers to prevent dust from depositing on joints. Units
can be provided with two types of "X" or "O" quick couplings, shown in the following
figures.
"X" joint connection:
1. Remove covers.
2. Check that the gasket seal on the male joint is lubricated with system fluid.
3. Move the female joint and tighten the rotating nut on the male joint.
4. Tighten the union of the two parts to the appropriate torque listed using
appropriately sized spanners (in the hexagonal body of the joint and the unit
nut) until the two sides are connected to the bottom or until you feel definite
resistance.
Figure 9: "X" quick coupling type