Round pipes
An inner diameter of 0 8" (200 mm) is recommended.
Flat ducts
The inner cross-section must correspond to the diameter
of the round pipes.
Ø 8" (200 mm) approx. 50.3 inches
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
Ventilator Performance Calculation
2
2
(324 cm
)

Checking the wall

The wall must be level, vertical and adequately load-
bearing.
The depth of the bore holes must be the same length
as the screws. The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used for
other structures.
11