Appliance dimensions
24" (609 mm)
30" (762 mm)
36" (914 mm)
A
Only for circulating-air mode:
*Max. 42 9/16" (1081 mm)
*Min. 28 1/4" (718 mm)
Only for ducted operation:
*Max. 38 7/8" (988 mm)
*Min. 24 9/16" (625 mm)
Safety clearances
WARNING
RISK OF FIRE
Grease deposits in the grease filter can catch fire. The
given safety clearance must be observed to avoid
heat buildup. Observe the specifications for your
cooking appliance. If gas and electric cooktops are
used together, the largest given clearance applies.
The appliance may only be installed directly next to a
cabinet or wall on one side. The wall or cabinet
clearance must be at least 1/16" (2 mm).
The clearance between the shelf on the cooktop and the
bottom of the extractor hood may not be less than 24"
(610 mm) in the case of electric cooktops and 30"
(760 mm) in case of gas or combined ranges.
If the installation instructions for the gas cooking appliance
specify a larger distance, this must be taken into account.
10
Electrical cooktop
Gas cooktop
min. 27" (686 mm)
Fan operation
Note: Ventilation may not exit through an already
operational smoke or exhaust chimney, nor a duct used for
ventilating furnace installation areas.
If the ventilation is intended to pass through a smoke or
exhaust that is not in operation, the responsible area
heating inspector must give approval.
If the ventilation passes through an external wall, use a
telescope wall sleeve.
Ventilation line
Note: The device manufacturer does not assume any
warranty for complaints attributable to the pipe section.
The ventilation opening and the exhaust air ducts must
be made according to the local circumstances.
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as large
a pipe diameter as possible.
As a result of long rough exhaust air pipes, many pipe
bends or too-small diameters, the optimum extraction
performance is not achieved and fan noise is
increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Smooth the connection area of the pipes before
installation.
Seal the connection points of the pipes appropriately.