5. EMERGENCY OPERATION

Use this operation only when the remote controller is defective or lost, and with function of
emergency running, air conditoner can run automatically for a while.
When the emergency operation switch is pressed, the «Pi» sound is heard once, which means the
start of this operation.
When power switch is turning on for the first time and emergency operation starts, the unit will run
automatically in the following modes:
Room
Température
temperature
définie
Above 23°C
26°C
Below 23°C
23°C
It is impossible to change the settings of temp. and fan speed, It is also not possible to operate
in TIMER or DRY mode.

6. TEST OPERATION

Test operation switch is the same as emergency switch.
Use this switch in test operation when the room temperature is below 16°C, do not use it in the
normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the «Pi»
sound twice, release your finger from the switch, release your finger from the switch : the cooling
operation starts with the air flow speed «Hi».
Under this operation mode, the fan motor of indoor unit will run in high speed.
Timer mode
Fan speed
No
AUTO
No
AUTO
51
Operation mode
COOL
HEAT
Wall mounted DOJO R32