CHECKING FOR GAS LEAKS
Soap and water solution or other material
acceptable for the purpose shall be used in locating
gas leakage. Matches, candle flame, or other
sources of ignition shall not be used for this
purpose. Check entire piping system for leaks.
LIGHTING INSTRUCTIONS
When griddle is first lit, it will smoke until the
preservation oils and impurities are burned off.
1. Turn off main valve to unit and wait 5 minutes
to clear gas.
2. Turn off all knobs and pilot valves.
3. Turn on main valve and light all pilots.
4. Turn burner knobs to desired setting.
5. To turn burners off, turn knobs off.
NOTE: The griddles are equipped with standing
pilots and should be lit immediately after the gas is
turned on.
LIGHTING INSTRUCTIONS (TCHSB &
TSPB SERIES)
1. Turn the thermostat knob(s) and pilot valves
to "OFF" position. CAUTION: If gas valves
have been on and gas has escaped through the
burners, turn unit off and wait 5 minutes to
clear gas.
2. Turn on pilot valve, depress and hold reset
button, light pilot, hold reset button for 60
seconds or until pilot stays lit (repeat for all
pilots).
3. Set thermostat(s) to desired temperature.
4. If burners do not light repeat steps 1 through 4.
5. Turn off thermostats and pilot valves for
complete shutdown.
PILOT LIGHT REGULATION
The pilots on this griddle have been turned off at
the factory. Adjust pilot light flames as small as
possible, but high enough to light burner
immediately when burner valve is turned on high.
ADJUSTING SAFETY PILOTS (SERIES
TCHSB & TSPB ONLY)
A rotor valve is provided to manually adjust pilot
flame size. "OFF" and "ON" positions are indicated
on valve. By slowly turning the adjustment knob, a
desirable pilot flame can be obtained.
BURNER ADJUSTMENT (MODELS 615MB,
624MB, 636MB, and 648MB ONLY)
1. Turn burner valve knob to "HI" position.
2. Slowly decrease opening of air shutters to
give a soft blue flame having luminous tips,
then slowly increase openings to a point where
the yellow tips disappear and a hard blue flame
is obtained.
BURNER ADJUSTMENT (MODELS 615TB,
624TB, 636TB, 648TB, TCHSB & TSPB
ONLY)
1. Push dial in and set thermostat of one burner
to 450°F (229.9°C).
2. Observing flame through lighting hole, close
the air shutter to give a soft blue flame having
luminous tips and open to a point where the
yellow tips disappear and a hard blue flame is
obtained. Repeat for all burners.
BURNER OPERATION (MODELS 615MB,
624MB, 636MB, and 648MB ONLY)
To ignite burners, turn burner valve knob to "HI"
position. Each burner is controlled by an individual
high-low, on-off valve. An infinite number of
temperatures may be obtained by turning the
burner valve knob to any position between high and
low.
OVERNIGHT SHUTDOWN
Turn knobs to the off position to turn burners off.
7