Dip switch settings and distances for connection between Ref.1092/300 and Ref.1092/316
DIP SWITCH
SETTINGS
*
For distances close to or higher than 1200 metres, use of an Urmet Domus Ref.1092/302 active
transmitter (instead of Ref.1092/300 passive transmitter) is recommended.
Important note:
Table 3 shows the approximate dip switch settings according to distance. This parameter may vary
according to the quantity of wire used for system installation.
The distances may vary according to the wire quality also when the latter is made by the same
manufacturer as the devices.
The distances shown in the table refer to the use of colour cameras. Higher distances may be
obtained using black and white cameras.
Consider that the distances may decrease if the devices are used with DVR apparatuses.
DS1092-020B
(PASSIVE - ACTIVE)
DISTANCE (m)
250 ÷ 350
350 ÷ 450
450 ÷ 550
550 ÷ 630
630 ÷ 690
690 ÷ 750
750 ÷ 810
810 ÷ 870
Table 3: distances with 24 AWG UTP CAT5 cable
DIP SWITCH
SETTINGS
DISTANCE (m)
870 ÷ 950
950 ÷ 1050
1050 ÷ 1150
1150 ÷ 1235
1235 ÷ 1315 *
1315 ÷ 1385 *
1385 ÷ 1460 *
1460 ÷ 1530 *