Daily Maintenance - Abicor Binzel EWR BASIC Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EWR

10.1 Daily maintenance

11 Troubleshooting
Fault
No gas during welding
Insufficient gas in the
process
Gas flow does not change
in proportion to the
welding current
Tab. 8
Troubleshooting
BAL.0253.0 • 2017-04-07
• If necessary, clean the EWR with a dry cloth.
• Check the EWR, power supply, shunt and gas hoses daily for damage and
replace them, if necessary.
DANGER
Risk of injury and device damage when handled by
unauthorised persons
Improper repair work and modifications to the product may lead to serious
injuries and damage to the device. The product warranty will be rendered
invalid if work is carried out on the product by unauthorised persons.
• Operating, maintenance, cleaning and repair work must only be carried
out by qualified personnel (in Germany, see TRBS 1203).
Please observe the attached 'Warranty' document. In the event of any doubts
and/or problems, please contact your retailer or the manufacturer.
NOTICE
• Please also consult the operating instructions for the welding
components, such as power source, welding torch system.
Cause
• Gas supply closed
• Impurities in the EWR
• Additional control element or gas
limitation in the gas supply
• Shunt not connected
11 Troubleshooting
Troubleshooting
• Open the gas supply
• Apply compressed air with
max. 5 bar to the gas supply
line and then to the gas
discharge line.
(The EWR must be connected
to the power supply and
switched off for this purpose.)
• Remove the additional control
element or gas limitation in the
gas supply
• Connect shunt
EN - 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ewr proEwr tig100165100084100085

Table des Matières