English
Installing the Unit
Use the following procedure to install the unit using the supplied
angle brackets. Refer to the OPTIONS AND ACCESSORIES
section near the back of this manual for other installation
options.
NOTE: Consult the manufacturer of the countertop material for
application information before installing the unit.
1. Position the unit on a flat surface with the display lights
facing down.
2. Install the angle brackets on each end of the unit.
NOTE: The angle brackets are shipped loose in the carton.
On each end of the unit:
a. Remove the two angle bracket screws.
b. Align the angle bracket with the mounting holes on the
unit. Secure the bracket with the two angle bracket
screws.
Angle Bracket
Angle Bracket Installation
NOTE: The angle brackets provide the required 1-1/2" (38 mm)
minimum clearance above the unit.
3. Fasten the angle brackets to the underside of the shelf
using appropriate fasteners (not supplied by Hatco). Make
sure the unit is facing the desired direction with the wire
leads on the proper side before fastening the unit to the
shelf.
Shelf Installation
4. Route the wire leads toward the installation location for the
control box.
Form No. NLXM-1213
Installing the Control Box
Use the following procedure to install the control box.
NOTE: Units can be ordered with up to ten feet (3 m) of wire
Control box must be mounted in a vertical surface.
Mounting control box in a horizontal surface may result in
the collection of liquids and lead to electric shock.
1. Make the appropriate cutout in the vertical surface where
the control box will be installed. Refer to the illustration
below for cutout dimensions specific to the size of the unit.
NOTE: Make sure a minimum depth of 5-1/4" (133 mm) is
Angle Bracket
Screw
NOTE: Make sure the width of the control box cutout does not
2. Complete the routing of the wire leads from the unit to meet
up with the wire leads on the control box.
3. Route the wire leads from the power supply to meet up with
the wire leads on the control box.
4. Remove the four front cover mounting screws and pull the
front cover off of the control box.
Shelf
7
leads, depending on the installation location of the
control box.
WARNING
available behind the vertical surface for the depth of the
control box and wires.
205 mm
(8-1/8")
Control Box Cutout Dimensions
exceed the above dimension.
INSTALLATION
98 mm
(3-7/8")
continued...