MultiMeasure Studio
We recommend using our "MultiMeasure Studio"
software. The scope of delivery of the flow rate con-
trol unit includes the standard version of MultiMeas-
ure Studio, which includes all our basic functions and
is available for download on our website. By means
of this software, you can easily record, analyse and
evaluate the generated USB data. You can comfortably
create protocols of measurement data or use the data
as basis for creating offers and invoices.
Find out how to install MM Studio
or expand the basic version to
include interesting functions un-
der http://de.trotec.com/service/
services-uebersicht/downloads/

05. DeCommISSIonInG

The display shows the subsequent drying (E). The
subsequent drying has been completed.
• Remove the humidity sensor from the compressor,
and store it in the holding bracket of the flow rate
control unit.
• Store the air sensor at the flow rate control unit.
• Store the antenna with the antenna cable at the
DA 4 M flow rate control unit again.
• Remove the hose connections.
Pay attention to possible residual water in the
hoses.
• Disconnect the power plug.
Before maintenance, service or repair work,
always disconnect the electrical power plug
and the connection hoses and ensure that the
device is de-energised.
B - 5
Operating manual – DA 4 / DA 4 M Flow Rate Control Unit

06. CARe AnD mAIntenAnCe

the DA 4 may only be serviced, opened and
maintained by professional users.
Upon completion of the work, the device should be
cleaned.
• Disconnect the power plug.
• Remove the hose connections.
• The hose passageways of the DA 4 may be
cleaned with water and suitable brush or, if ap-
plicable, with compressed air.
high-pressure cleaners are not allowed.
• The casing can be wiped clean with a moist cloth.
Here, splashing water is to be avoided.
• The casing of the MultiQube series is made of
ABS plastic. For this reason, avoid the use of
chemical or solvent-containing cleaning agents.
Test the cleaning agent at a covered spot if
required.
• Regularly check cables and plugs of the connec-
tion line and sensors. Damaged cables and plugs
are to be removed.
• The valves of the flow rate control unit are only ad-
missible for a flow of air, water and foreign bodies
up to 15mm. Clean the core drilling holes before
using the insulation drying modules.
• The valves are maintenance-free. No lubrication
is required.
• Maintenance and repair work should only be per-
formed by Trotec. If such work is performed by
third parties, the guarantee and liability become
void.
• The DA 4 casing is made of ABS plastic. White
discolouring might be created by material tension.
Such discolouring, which is similar to cracking,
has no impact on the functionality of the device
EN