Commissioning; Operation - Trotec DA 4 MultiQube Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

In order to avoid faults, the device is to be cleaned at
regular intervals during or after each use, depending
on individual loads.
When using extension cables or cable drums, the ca-
ble must always be rolled off completely.

03. COMMISSIONING

• Ensure that the inlets and outlets are free. Remove
any plugs or foreign bodies from the nozzles and
lines.
• Install the required elements for the insulation
layer vacuum drying (water extractor, filter, com-
pressor and exhaust mufflers).
• Connect the hoses coming from the core drilling
holes to one side of the DA 4.
• Connect the hoses coming from the DA 4 with the
water extractor for the insulation layer drying.
• Plug the black humidity sensor by means of the
screw-in adapter into an inlet of the 4-fold dis-
tributor at the compressor (figure 2).
• Place the grey room air sensor near the condensa-
tion dryer.
(Fig. 2: arrangement of the MultiQube elements)
B - 3
230 V
Operating manual – DA 4 / DA 4 M Flow Rate Control Unit
• Connect the device to the power supply.
• The device is now ready for operation.
• Carry out a reset:
Hold down the key (9). After 4 seconds, a countdown
appears on the display. Once the countdown has
finnished, please release the key.
• Follow the instructions on the display:
- "Self test"
> Press key
- "Drying programme"
> Press key
If a different text is visible on the display, press the
key for 6 seconds in order to reset the programme.
The device will start.
The DA 4 may only be commissioned and oper-
ated by professional users.

04. OPERATION

Drying process
The DA 4 separates the drying process into several
drying cycles and/or drying intervals