6 Assembling and installing
The assembly and installation must be
performed only by skilled personnel.
The product may be interfaced with devices
not manufactured by VIDEOTEC. VIDEOTEC
recommends a test prior to installation.
VIDEOTEC will not be liable for any
installation costs or lost revenues in the event
a compatibility problem will occur.
6.1 Installation
6.1.1 How to open the housing
Loosen the 2 screws on the side, turn the cover and
the upper half of the body about the opening hinge
axis.
Fig. 1
At the end of istallation and cabling
operations close the housing.
6.1.2 Removal of the slide
To remove the slide it is necessary to unscrew the
fixing screws as shown in figure.
Fig. 2
6
6.1.3 Cable glands assembly
For the internal cable routing brackets it is
necessary to use the sealing ring kit (OWBIP).
The reduced space does not allow the use of
the supplied cable glands. The kit must be
bought separately.
Inside the supply are 3 cable glands that must be
installed at the bottom of the housing as shown
in figure. The cable glands that are not used must
be sealed with the cap to avoid water entering the
housing.
Fig. 3
6.1.4 Installation of the GEKO IRH
illuminator (optional)
Maximum power of the illuminator must not
exceed 6W.
To install the illuminator it is necessary to use
the illuminator bracket (OSUPPIR). The kit
must be bought separately.
Use the cable glands or the smallest sealing ring to
avoid water entering the housing.
For installation information on the illuminator on
housing refer to the product's use and installation
manual.
For further details on configuration and use refer to
the relative chapter (6.1.4 Connection of the GEKO
IRH illuminator (optional), page 8).
MNVCHPVHPOE_1511_EN