OPERATING STATUS
LED
LED Status Apparatus Status
LD1 (Power
Off
supply)
On
LD2 (Ca-
Off
mera)
On
1 flashing
2 flashings
5 flashings
9 flashings
LD3 (Demi-
Off
sting)
1 flashing
2 flashings
On
LD4 (He-
Off
ater)
1 flashing
On
LD5 (Illumi-
Off
nator)
1 flashing
LD6
Off
(Delayed
1 flashing
activation)
On
Tab. 4
MNVCHPVHPOE_1511_EN
The device is not powered
The device is correctly powered
The camera is not connected or
Cold Start is active
The camera is correctly powered
The camera has a low identifica-
tion resistance
The camera has a high identifica-
tion resistance
The camera has an excessive
energy consumption
The camera requires more energy
than the available
Demisting was not correctly
detected
Standard demisting is inactive
The anti-ice system (optional) is
inactive
Demisting, or anti-ice system, is
in function
Heating is not available or power
available is not sufficient
Heating is inactive
Heating is active
The illuminator (optional) is not
detected or the available power is
not sufficient
The illuminator is correctly
powered (illuminator activation is
controlled by its photocell)
Heating is not available
The pre-heating procedure is
inactive
The pre-heating procedure is
underway
9 Maintaining and cleaning
9.1 Maintaining
9.1.1 Kit for upgrading of the systems
Remove the slide (01), the electronic board (02) and
the heating (03).
02
Fig. 15
If the housing is provided with blower with double
filter for air renewal it is also necessary to replace the
blower with those equipped in the kit.
Fig. 16
For kit installation information refer to chapter 6
Assembling and installing, page 6.
9.2 Cleaning
9.2.1 Window and plastic cover cleaning
Avoid ethyl alcohol, solvents, hydrogenated
hydrocarbide, strong acid and alkali. Such
products may irreparably damage the
surface.
We recommend using a soft cloth with neutral soaps
diluted with water or specific products to clean the
glasses lenses.
01
03
11