English
Choice of installation materials
For non-flammable materials select panels/brick with a thermal resistance greater than
0.03 m
xK/W. Thermal resistance is defined as the wall thickness (in m) divided by the
2
wall lambda value.
Consult your installer/chimney sweep.
During the test the stove was installed in a cabinet made of non-flammable building
panels 50 mm Calcium silicate (Skamotec 225).
Installation measurements
Valid for installation in non-flammable panels, or in brick.
If other materials are used, they must have the same or better properties.
To obtain the necessary distances from the stove to the panel/brickwork, the interior
measurements of should be min. 528,2mm X 924,3mm If these are observed, the exte-
rior can be adjacent to a flammable wall. There must be a top plate in the cabinet just
above the convection outlet.
A fireplace insert must never be installed too tightly as steel expands during heating.
18
18
attika
RAIS/
- User manual for VISIO 3-1