English
Interruptions of operations
Smoke spillage around the door
This may be due to insufficient draft in the chimney <12Pa
• Check whether the flue or chimney is blocked
• Check whether the extraction hood is switched on and, if so, switch it off and
open a window / door near the stove for a short period.
Soot on glass
May be caused by
• excessively wet firewood
• the damper regulation is too low
Ensure the proper heating of the stove when firing up, prior to closing the door
Stove is burning too strong
Possible causes
• leak around the door seal
• chimney draft too large> 22 Pa, draft control regulator should be installed.
Stove is burning too weakly
Possible causes
• insufficient amount of wood
• insufficient air supply for room ventilation
• unclean smoke channels
• leaky chimney
• leakage between chimney and flue
Low draught in the chimney
Possible causes
• temperature difference too small, e.g. due to poorly insulated chimney
• outside temperature is high, e.g. in the summer
• no wind
• the chimney is too low and sheltered
• false air draught in the chimney
• chimney and flue pipe is blocked
• the house is too dense (lack of fresh air intake).
• negative smoke extraction (poor draft conditions)
In the case of a cold chimney or difficult weather conditions you can compensate by
adding more air to the stove than usual.
If your stove continues to malfunction, we recommend that you contact your RAIS
distributor or chimney sweep.
attika
RAIS/
- User manual for VISIO 3-1
33
33