Vimar Elvox 69PH Guide Rapide page 7

Masquer les pouces Voir aussi pour Elvox 69PH:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
69PH
NOTE: All programming on 69PH can be cancelled simultaneously
using the "RESET DEFAULT DATA" procedure.
NOTE: The ID with 69PH installed over Horizontal Bus can only be
assigned with programmer 950C or SaveProg.
4) ID attribution for relay operation if more than one
69PH is present in the system
The default ID of device 69PH is 1
When operating as RELAYS, there may be up to eight 69PH modules
in the system, to a total of 16 actuators. In this case the dip switches
must be used to assign an ID to each 69PH module. The indoor
station must have multiple suitably programmed buttons to activate
auxiliary relays.
NOTE: More than one relay can be programmed with the same ID if
simultaneous activations controlled by the same button are required.
NOTE: RL1 and RL2 are activated in the DEFAULT configuration by
buttons P2 and P3 on the indoor station, corresponding to AUX 1 and
AUX 2 of each configured GROUP.
The ID of the relay module 69PH is manually assigned by setting the
"Dip-switch for assigning ID." For the configuration please refer to Fig-
ure 1 and Table 4.
69PH
Operation
RL1=Auxiliary 1 and
1 (ID 1)
RL2=Auxiliary 2
RL1=Auxiliary 3 and
2 (ID 2)
RL2=Auxiliary 4
RL1=Auxiliary 5 and
3 (ID 3)
RL2=Auxiliary 6
RL1=Auxiliary 7 and
4 (ID 4)
RL2=Auxiliary 8
RL1=Auxiliary 9 and
5 (ID 5)
RL2=Auxiliary 10
RL1=Auxiliary 11 and
6 (ID 6)
RL2=Auxiliary 12
RL1=Auxiliary 13 and
7 (ID 7)
RL2=Auxiliary 14
RL1=Auxiliary 15 and
8 (ID 8)
RL2=Auxiliary 16
Tab. 4
Dip
Dip
Dip
Dip
1
2
3
4
OFF OFF OFF OFF
ON
OFF OFF OFF
OFF
ON
OFF OFF
ON
ON
OFF OFF
OFF OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
EN
Programming relays over horizontal Bus
CAUTION: TO ACTIVATE THE RELAYS CONNECTED TO THE
HORIZONTAL BUS, IT IS NECESSARY TO REMAP THE ROUTER
69RS ASSIGNING AN "EXTENDED" IDENTIFICATION ID (SEE
ROUTER INSTRUCTIONS art. 69RS).
THE EXTENDED ID CAN ONLY BE ASSIGNED VIA THE PRO-
GRAMMER 950C OR SAVEPROG
Horizontal Bus manual programming
1) RESET DEFAULT DATA
The reset procedure allows factory settings to be restored (default
configuration).
- Press and hold down buttons RST and P1 simultaneously.
- Release RST but continue to hold down P1 until the LED begins to
flash.
- While the LED flashes release P1 and press P1 immediately.
- Hold down P1 until the LED goes out.
- Release P1.
NOTE: In the default configuration, the operating mode is of a mon-
ostable relay.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elvox videocitofonia 69ph

Table des Matières