Truma TG 1000 sinus power inverter

Safety instruction

All repairs must be carried out by an expert!
The alternator output must be at least 110 A to provide a
Truma Saphir vario or Saphir compact air conditioning unit
with an adequate power supply.
The equipment may only be used:
– In conjunction with batteries with the specified nominal
voltage in fixed installations. (minimum battery capacity
90 Ah)
– For powering mains voltage equipment up to the specified
maximum electrical output of 1000 W.
– If it is ensured that only one consumer (max. 1000 W) is
connected. No parallel operation of multiple consum-
ers. Multiple sockets must not be used. 2-pole disconnec-
tion (L and N) must take place if transfer switches are being
used.
– In rooms that are protected from water, moisture, dust
and aggressive battery gasses, and in non-condensing
environments.
The device must never be used in locations where
there is a risk of dust or gas explosion.
– If the ambient temperature is within the permitted usage
limits.
– If the ventilation openings on the cover and the front (termi-
nal strip) are exposed and not covered by luggage, towels or
clothing etc.
Check voltage-carrying cable at regular intervals for breaks,
loose connections etc.
The device must be fully disconnected during electrical
welding work and when working on the electrical system.
The device must not be opened (dangerous high voltage may
be present, even after the battery has been disconnected).
Keep children away from the power inverter!
6
Operating instructions

Intended use

The TG 1000 sinus power inverter has been developed for
operating a Truma air conditioning unit (e.g. the Saphir vario
or the Saphir compact) or another consumer with electrical
power consumption of up to 1000 W.
The power inverter generates an alternating voltage (sine
wave) of 230 V ~ from a direct voltage of 12 V.
Connections
TG
1000 sinus
230 VAC
Remote
Fuse (T 6,3 A)
In
Out
a
c
b
d
a = 230 V ~ mains input voltage connection via 3-pin socket
(Wago)
b = T 6.3 A fuse (always replace with identical fuse)
c = 230 V ~ output voltage connection via 3-pin plug (Wago)
d = Remote (control panel accessory connection)
e = Com connection (communication – RJ 10 plug) to air
conditioning unit
f = LED (ready)
g = Cover (to open, press and release flap of terminal strip at
controller)
h = Connecting bolt (M8), auxiliary battery positive terminal
i = LED (mains current operation)
j = 5-pin plug (5 x flat plugs 6.3 mm), pin assignment from
left to right:
D+
= 12 V signal from alternator when vehicle engine
is running
Out
= 12 V output, max. 1 A, for external relay for
example, present when pin 5 is "On"
Sens+ = Starter battery positive terminal connection
(battery voltage monitoring)
Sens- = Starter battery negative terminal connection
(lower battery voltage monitoring)
On
= 12 V input for switching on the power inverter
if neither the air conditioning kit nor the autarky
kit is being used (switches 12 V output "Out")
k = LED (fault)
l = Connecting bolt (M8), auxiliary battery negative terminal
+
Bat
Com
Bat
e
e
h
j
l
f
g
i
k