CONTROL CARD FOR ONE OR TWO 230 Vac SINGLE-PHASE MOTORS FOR
MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
INCORPORATED ELECTRONIC TORQUE LIMITER
ELECTRONIC PEAK LOAD CONTROL
CONTROL OF THE SENSITIVE EDGE according to the EN 954-1 standard
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input). The
go off only when the controls to which they are associated are operated.
The red DL5 LS LED must be off (corresponding to the Normally Open OPEN/CLOSE input). It
only comes on when it is activated by the control to which it is associated.
The red DL7 LS LED must be on (giving indications during the programming of the radio control
device).
Power input to board
Max motors nominal power
Fast acting fuse for protection of input power supply 230 Vac (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
Fast acting fuse for protection of auxiliary circuits 24 V dc (F2 - 5x20)
Working temperature
DL1
SENSITIVE EDGE green LED signal
DL2
OPEN LIMIT SWITCH green LED signal
DL3
CLOSE LIMIT SWITCH green LED signal
DL4
External input STOP green LED signal (terminal 17)
DL5
OPEN/CLOSE button red LED signal
DL6
PRESSURE-SENSITIVE EDGE green LED signal
DL7
Radio receiver programming red LED signal
DL8
Integrated push button panel Stop green LED signal
K892M
English

OVERHEAD DOORS

TESTING
230 Vac - 50 Hz
400 W
F 6,3 A
230 Vac
24 Vac
F 500 mA
-20°C ÷ +70°C

DIAGNOSTICS LED