Fronius Acctiva Professional Mode D'emploi page 28

Masquer les pouces Voir aussi pour Acctiva Professional:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Back-up mode
Provides a power supply to the vehicle while the battery is being changed. Electrical
equipment such as window lifters, etc. may be used. Because the charger output voltage
is regulated, the vehicle electronics are not adversely affected.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Change battery
11. Connect vehicle pole terminals to correct poles on new battery
12. End back-up mode by pressing Start/Stop button
Important! If the Start/Stop button is not pressed, the charger will still be in back-up
mode when next switched on.
13. Disconnect charger from mains supply
14. Remove charging terminals from vehicle pole terminals
Automatic/fixed
This menu item
voltage selection
-
-
1.
2.
3.
4.
Warning! Risk of serious damage as the result of
-
incorrectly connected charging terminals. The terminal polarity reversal
facility is inoperative in „Charging deep-discharge batteries back-up"
mode.
-
incorrectly set vehicle voltage.
Connect charging terminals to correct poles and ensure proper electrical
connection to vehicle terminals. Note vehicle voltage.
Switch off engine
Turn off ignition
Plug in charger mains plug
Press and hold Start/Stop button for approx. 5 sec. - „Charging deep-discharge
batteries/back-up mode" menu item is activated
Select battery voltage by pressing Up/Down buttons
Example: 12 V vehicle voltage
Confirm selected voltage by pressing Start/Stop button
Connect charging terminals to correct vehicle pole terminals
Confirm correct terminal connection prompt by pressing Start/Stop button
Charger starts back-up mode
permits automatic voltage detection when charging starts (factory setting)
allows fixed setting for the battery being charged (e.g. only used to charge 12 V
batteries)
Plug in charger mains plug
Press and hold Info button for approx. 5 sec - „Automatic/fixed voltage selection"
menu item is activated.
Select voltage by pressing Up/Down buttons
Automatic battery voltage
selection
Confirm selected voltage by pressing Start/Stop button (10)
If no buttons are pressed within 5 seconds, the charger
returns to the main menu.
Example: manually fixed
setting for 12 V battery
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Acctiva professional 42

Table des Matières