Surface-mounting of sensor cable, version 1
The cable is passed through the cable duct in the insert.
• Pass the the sensor cable (1) through opening (2) behind the supporting
• Lead the cable directly through the duct to the terminal block (4). The cable
34
frame (between wall and supporting frame) into the cable duct (3) in the
insert.
must follow the duct closely without any loops in the 230 V section of the
insert.
GB
Connection to the terminal block in the insert:
Connect the sensor cable in acc. with fig. E.
The screws of the block must be at the bottom.
Left:
glass breakage sensor signal line
Center:
ground
Right:
sun / twilight sensor signal line
Wire marking:
Sensors:
'Ground' = marked grey
Adapter and extension cable:
'Sun' = marked grey
'Ground' = middle wire
If the the sun / twilight sensor and the glass breakage sensor are to be used
at the same time, an adapter must be installed (to be ordered separately).
Connect the adapter directly to the attachment by means of the connector or
to the insert with the 3-pole terminal block (connector cut off).
The adapter is equipped with 2 jacks for connection of the sensor plugs
35