Exhaust System Requirements - Kenmore 137631400 A Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Requirements

Exhaust system requirements

Use only 4 inch (102 mm) diameter rigid or fl exible
metal duct and approved vent hood which has a swing-
out damper(s) that open when the dryer is in operation.
When the dryer stops, the dampers automatically close
to prevent drafts and the entrance of insects and rodents.
To avoid restricting the outlet, maintain a minimum of 12
inches (30.5 cm) clearance between the vent hood and the
ground or any other obstruction.
WARNING
FIRE HAZARD
Failure to follow these instructions can create excessive
drying times and fi re hazards.
The following are specifi c requirements for
proper and safe operation of your dryer.
WARNING
FIRE HAZARD
Do not install a clothes dryer with fl exible plastic or
metal foil venting materials. Flexible venting materials
are known to collapse, be easily crushed and trap lint.
These conditions will obstruct clothes dryer airfl ow and
increase the risk of fi re.
If your present system is made up of plastic duct or metal
foil duct, replace it with a rigid or semi-rigid metal duct.
Also, ensure the present duct is free of any lint prior to
installing dryer duct.
Correct
Correct
6
Incorrect
Incorrect

Publicité

Table des Matières
loading

Table des Matières