Troubleshooting
Use this table to see possible solutions for problems with the blower If these suggestions do not
solve the problem, see "Warranty and Service"
SYMPTOM
Motor does
not run or runs
intermittently
Air volume and/
or speed from
nozzle decreases
noticeably
Excessive vibration
Turbo button not
operating
Battery pack does
not charge
22
Troubleshooting
POSSIBLE CAUSE
Battery discharged
Trigger lock-out not
pressed
Battery pack not fully
inserted
Battery contacts dirty
Battery pack too hot or
too cold
Electronics cooling vent
clogged
Air intake clogged
Nozzle clogged
Blower fan damaged
Use of a battery pack
with capacity of less than
2 4 Ah
Battery pack over/under
temperature protection
is activated
Dirty or damaged
contacts on battery pack
or charger
Battery pack is at the
end of its life
Charger faulty
RECOMMENDED ACTIONS
Recharge See "Battery Pack and Charger"
Press the trigger lock-out before squeezing the
trigger switch See "General Operation"
Press the battery pack into the battery port until it
clicks into place
Remove the battery pack, remove debris from the
battery port and then clean the contacts with a clean,
dry cloth
Allow the battery pack to warm or cool to within the
operating temperature range of 32°F to 104°F (0°C
to 40°C)
Clear any debris from the vent to provide
unobstructed airflow to the variable trigger
Clear debris from the intake screen
Remove the battery, then remove the nozzle and
clear debris from the nozzle
Have the blower inspected at an approved service
location
The turbo button will not operate with capacity of
less than 2 4 Ah Insert higher capacity battery pack
to operate turbo button
This may occur when the blower is run continuously
or exposed to high ambient temperatures Allow the
battery pack to reach the acceptable temperature
before charging See "Battery Pack and Charger"
Inspect the contacts on both the battery pack
and charger If necessary, clean according to the
instructions in this manual Reinsert battery pack into
the charger, making sure it is fully seated
All batteries have a finite life If the battery pack
is more than two years old or has been recharged
frequently, it may be time to replace it Replace only
with the battery pack specified for this blower
Have the function checked at an approved service
location
Blower Model BL300