2.4.
FLOW CHART - MENU
LANGUAGE
BUZZER
ON - OFF
SET DEGREES
DISPLAY
10 - 100%
TECHNICAL
SETTINGS
SYSTEM
( PR06 = Off )
3.
HOT WATER KIT
3.1.
CONNECTION
All operations must be performed with mains power disconnected.
IMPORTANT: after having transported / handled the WATER CONNECTION KIT, check tightness of all the compression nuts on the copper
pipes. Take special care when connecting the KIT to the plumbing system to avoid bending the copper pipes in the KIT. To counter the
tightening force exerted on the plumbing system connection pipe, use a wrench or other tool on the terminal in the KIT being connected.
IMPORTANT: after having connected the KIT to the plumbing system, check tightness of all the compression nuts on the copper pipes.
THERMAL RELIEF VALVE (VST) – SAFETY VALVE (VSP)
The VST (Thermal Relief Valve) and VSP (Safety Valve) valves are installed in the plumbing system at the heating appliance outlet, less
than one metre from the latter, as specified by the standards in force regarding safety devices.
3.2.
OPERATION
The controller allows SIMPLE DHW Kit (6012014), COMBINED DHW Kit (6012015) and
NORDICA, to be controlled. It is recommended to follow the wiring connection diagrams of the flow switch and pumps to the controller as
shown in diagram 9, 10,
11
It is recommended to size the heating device correctly by considering the usage habits of domestic hot water.
If necessary, the operating thresholds of circulators C1 and C2 can be set to values below 60 °C and 70 °C, respectively. It is recommended
to use this option as least as possible as particularly cold water affects the integrity of the heat exchanger.
Activate this option by entering the "TECHNICAL SETTINGS" menu, then accessing the "PRODUCT TYPE" menu, entering code "33" and
selecting the PR07 = 2 value. Therefore, the threshold adjustment range of the pumps allows the temperature to be decreased to 10 °C
(only valid for DHW kits).
13
6092000 - IT - EN - DE - FR
ITALIANO
ENGLISH
FRANCAIS
ESPANOL
°C- F
DEUTSH
SETTINGS FACTORY
CODE 44
TEST OUTPUTS
STATUS Stove
PRODUCT
CODE 33
PR08 BOILER (On / Off )
PR09 SET BOILER Max
PR10 SET BOILER Min
PR11 PUFFER ( On / Off
PR12 thermal differential to PUFFER On (5 - 12°C) Default = 7°C
PR13 thermal differential to PUFFER Off (3 - 8°C)
and 12.
COMPONENTI ACCESSORI PER TERMOPRODOTTI
PR01 CIRCULATOR 1 Threshold OUT 1 (55- 65°C)
PR02 CIRCULATOR 1 Delta OUT 1
TEST OUT 1
TEST OUT 2
PR03 CIRCULATOR 2 Threshold OUT 2 (65 - 75°C)
TEST OUT 3
PR04 CIRCULATOR 2 Delta OUT 2
I1= xx°C
Heating device
(
probe)
PR05 ANTIFREEZE Threshold
I2= xx°C
PUFFER
(
probe)
I3= xx°C
BOILER
(
probe)
I4= On / Off
(Flow switch)
PR06
0 = Heating device DSA
1 = All Inclusive
2 = WATER CONNECTION KIT
Default = 60°C
( 47 - 70°C )
Default = 30°C
( 30 - 46°C )
)
Default = 5°C
SEPARATOR
Default = Heating device 60°C
(1 - 5°C)
Default = 5°C
Default = Heating device 70°C
(1 - 5°C) Default = 5°C
(2 - 10°C)
Default = 5°C
Kit (6012021) , supplied by LA