Package description
Gateway description
REMOCON NET installation
Package description:
Gateway with power cable
Gateway wall plate
Gateway description
On/Off button
Bus BridgeNet LED
Serial communication LED (no
function)
4. Internet communication LED
5. First Confi guration button
6. 230V AC connector
7. LAN port
8. Serial port (no function),
9. External antenna port (GPRS-
Version)
10.TA port (no function)
11.Bus BridgeNet port
REMOCON NET installation
This chapter describes the installa-
tion procedure of REMOCON
NET. We recommend to start up
the procedure making first the
gateway connection with the heat-
ing product. After that, it will be
possible to connect the gateway to
the power supply and to fasten it to
the wall through the wall plate.
CAUTION!
The installation must be performed
by qualified personnel. Before its
assembly, switch off the power
supply of the boiler.
2 pole connection cable
Envelope with 3 wall plugs for
gateway wall plate
5
4
3
2
1
Opening the case
Open the front panel of the
gateway by removing the two
locking screws placed at the
bottom of the device (fi g. 1),
slightly rotate the cover (fi g.2)
and pull it down (fi g. 3).
Gateway link to the heating
product
Connect the two-core cable sup-
plied in the package to the Bus
BridgeNet port of the gateway,
using 1 orange connector also
supplied.
Connect the other end of the
cable to the Bus BridgeNet port
of the heating product, using
another orange connector.
Note:
The Bus BridgeNet cable is polar-
ized: to avoid any communication
issue respect the polarity between
all the products in the heating sys-
tem.