Switching off the cooler

➤ Empty the cooler.
➤ Switch the cooler off.
➤ Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
➤ Leave the cover slightly open. This prevents odour build-up.
6.8

Defrosting the cooler

Humidity can form frost in the interior of the cooling device or on the vaporiser. This
reduces the cooling capacity. Defrost the device in good time to avoid this.
A
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤ Take out the contents of the cooling device.
➤ If necessary, place them in another cooling device to keep them cool.
➤ Switch off the device.
➤ Leave the cover open.
➤ Wipe off the defrosted water.
6.9

Replacing the device fuse

D
DANGER! Danger of electrocution!
Disconnect the connection cable before you replace the device fuse.
➤ Pull off the connection cable.
➤ Pry out the fuse insert (fig. 4 2, page 4) with a screwdriver.
➤ Replace the defective fuse with a new one that has the same rating (T4AL 250V).