9 / MAINTENANCE
For all maintenance, adjustment or repair operations, prevent unintentional operation of electrical and
pneumatic circuits on the machine by padlocking the main isolating switch 19 and the valve 17.
(page 11)
Depending on the frequency of use. On the basis of 8 hours work a day:
Cleaning
- clean the Plexiglas screen with a soft cloth
- clean the offcuts outlet hopper
Belt inspection
- every 3 months
Blade sharpening
- good cutting is the result of good sharpening
We recommend contacting your dealer for this service.
TYPE OF BLADE RECOMMENDED FOR MULTI-PURPOSE
CUTTING
BLADES SPECIFICATION
Blade diameter
Teeth
Number of teeth
Body thickness
Norme : EN 847-1/ 1997
Never use high-speed (HS) steel blades.
PANNES
FAULT
Indicator lamp V1 on control panel (page 28) is
off.
The clamps operate but the blades aren't
moving.
Poor quality cut
: 350 mm.
: LR Positive.
: 108.
: 2.7.mm
POSSIBLE CAUSES
1/ Check the electrical power supply and the safety chain (red
indicators on panel), see diagram on inside of electrical control cabinet
door.
2/ Main isolating switch not engaged.
3/ Motor circuit-breaker not activated.
4/ Pressure poor (min. 6 bar).
5/ Cover is not locked
6/ Button 2 (CP Page 28) is locked.
7/ Fuses need to be changed.
1/ The blades have not been started up.
2/ Actuation of the two-hand control buttons > 3 sec.
3/ The waste drawer is too full and this is impeding
movement of the blades.
1/ Blades are turning in wrong direction (2 phases inverted).
2/ Blades need to be sharpened.
3/ Moulding is in an unstable position and is moving during cutting.
4/ Blade lowering speed is not suitable for the type of wood being cut.
5/ Small mouldings being cut without the small moulding clamp option.
CS969
39