3.2 Installation in Paramount
three 60-80 E
3.3 Installation in Paramount
three 95-115 E
Fig. 2: Gas line
7303554-01 07.11
Risk of electric shock! Prior to commencing any installation work, isolate the boiler
from the power supply and safeguard against unintentional reconnection.
- Remove pump replacement pipe from gas condensing boiler Paramount three
and install pump HEP 25-180-10 with the gaskets supplied
or
- Install pump HEP 25-180-10 externally
- To insulate the pump, fit insulation semi-shells if required
Risk of electric shock! Prior to commencing any installation work, isolate the boiler
from the power supply and safeguard against unintentional reconnection.
Risk to life from escaping gas! Prior to commencing any installation work, isolate
the gas supply to the gas condensing boiler.
Note: Prior to installing the pump HEP 25-180-10 in gas condensing boilers in the
Paramount three 95 E and WGB 115 E series, remove the gas line to the boiler gas
valve to permit access to the upper union nut.
- Remove gas line to gas valve (1)
- Remove pump replacement pipe from gas condensing boiler Paramount three
95-115 E and install pump HEP 25-180-10 with the gaskets supplied
- Refit gas line to gas valve with the gaskets supplied
Variable speed pump HEP 25-180-10
Installation
1
GB