47. Mid voltage alarm - 702 only
When the mid-point voltage deviation rises above this value for more than 10 seconds, the
alarm will be activated. This is a visual and audible alarm. It does not energize the relay.
See section 5.2 for more information about midpoint voltage.
Default
2%
______________________________________________________________
48. Clear mid voltage alarm - 702 only
When the mid-point voltage deviation falls below this value, the alarm is switched off. This
value needs to be less than or equal to the previous parameter.
Default
1,5%
4.2.4 Display settings
______________________________________________________________
49. Backlight intensity
The intensity of the backlight, ranging from 0 (always off) to 9 (maximum intensity
Default
5
______________________________________________________________
50. Backlight always on
When set the backlight will not automatically turn off after 60 seconds of inactivity.
Default
OFF
______________________________________________________________
51. Scroll speed
The scroll speed of the display, ranging from 1 (very slow) to 5 (very fast).
Default
2
______________________________________________________________
52. Main voltage display
Must be ON to display the voltage of the main battery in the monitoring menu.
53. Current display
Must be ON to display current in the monitoring menu.
54. Power display
Must be ON to display power in the monitoring menu.
55. Consumed Ah display
Must be ON to display consumed Ah in the monitoring menu.
56. State-of-charge display
Must be ON to display state-of-charge in the monitoring menu.
Range
0 – 99%
Range
0 – 99%
Range
0 – 9
Range
OFF/ON
Range
1 – 5
Step size
0,1%
Step size
0,1%
Step size
1
Step size
1
25