Truck Bed Mounting
A = Nut
B = Washer (3 per foot)
C = Mounting surface (truck bed)
D = Isolation mount
E = Spacer
F = Washer
G = Compressor mounting foot
H = Washer
J = Bolt

AIR INLET CONNECTIONS

CAUTION
Do not operate the compressor without air inlet filtration.
If the air around the compressor is relatively free of dirt, install the air
inlet filter(s) at the inlet connection(s) at the compressor. If the air is
dirty, pipe the filter(s) to a source of clean air. Refer to the manual for
remote air inlet requirements.

AIR DISCHARGE CONNECTIONS

WARNING
Do not use plastic pipe, soldered copper fittings, rubber hose,
or lead-tin soldered joints anywhere in the compressed air
system. All hoses, piping, fittings, air receiver tanks, etc. must
be certified safe for at least the maximum working pressure and
temperature of the compressor.
DO NOT USE PVC PLASTIC IN THE COMPRESSED AIR DISCHARGE
LINE.
CAUTION
If you will be using synthetic compressor lubricant, all
downstream piping material and system components must be
compatible. Refer to the following material compatibility list.
If there are incompatible materials present in your system, or
if there are materials not included in the list, contact Ingersoll
Rand for recommendations.
80445703 Rev. H
RELEASED 05/Apr/2018 15:16:08 GMT
GENERAL REQUIREMENTS

ELECTRICAL CONNECTIONS

PERMANENTLy CONNECTED ELECTRIC COMPRESSORS
GENERAL. The motor rating, as shown on the motor nameplate, and
the power supply must have compatible voltage, phase and hertz
characteristics.
WIRE SIZE. The electrical wiring between the power supply and
electric motor varies according to motor horsepower and other
factors. Install adequately sized power leads to protect against
excessive voltage drop during start-up. Refer to the applicable electric
codes in your area for information on selecting the proper wire
size and securing electrical connections. If you connect additional
electrical equipment to the same circuit, consider the total electrical
load when selecting the proper wire size. DO NOT USE UNDERSIZE
WIRE.
MAGNETIC STARTER. If the motor installed on your compressor has
a motor reset button, it does not require a magnetic starter. If the
motor does not have this button and the compressor does not have
a factory-installed starter, install a magnetic starter with thermal
overload protection. Follow the manufacturer's instructions for
installation. Ingersoll Rand cannot accept responsibility for damages
arising from failure to provide adequate motor protection.
SyNTHETIC COMPRESSOR LUBRICANT MATERIAL
COMPATIBILITy LIST
SUITABLE
Viton®, Teflon®, Epoxy (Glass Filled), Oil Resistant Alkyd,
Fluorosilicone, Fluorocarbon, Polysulfide, 2-Component
Urethane, Nylon, Delrin®, Celcon®, High Nitrile Rubber (Buna N.
NBR more than 36% Acrylonitrile), Polyurethane, Polyethylene,
Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked
Phenolics, Epoxy, Modified Alkyds (® indicates trademark of
DuPont Corporation)
NOT RECOMMENDED
Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer,
Varnish, Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate,
Low Nitrile Rubber (Buna N. NBR less than 36% Acrylonitrile), EPDM,
Ethylene Vinyl Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones,
Styrene Acrylonitrile (San), Butyl
NOTICE
All compressed air systems generate condensate which
accumulates in any drain point (e.g. tanks, filters, drip legs,
aftercoolers, dryers). This condensate contains lubricating
oil and/or substances which may be regulated and must be
disposed of in accordance with local, state, and federal laws and
regulations.
Use flexible piping at the compressor's discharge connection.
Use hard-welded or threaded steel or copper pipes and cast
iron fittings along the remaining air discharge line.
Slope the piping downward in the direction of airflow to
permit condensate to drain properly.
Use pipe thread sealant on all threads, and secure joints
tightly to prevent air leaks.
WARNING
Electrical installation and service must be performed by a
qualified electrician who is familiar with all applicable electrical
codes.
EN-5