WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
To replace worn parts, use only original spare parts.
Failure to comply with the above may give rise to risks for the operator, the
technicians, the persons, the pump and/or the environment that cannot be as-
cribed to the manufacturer.
L
TRANSPORT AND POSITIONING
The operators in charge of the assembly / disassembly must be informed and trained
on the dangers relating to the use of mechanical tools, even small ones.
The noise levels of the machine correspond to:
• The sound pressure level of the A weighted emission, in the working place, is less
than 78 dB.
Upon receipt, please check that the packing and the pump are intact and have not
been damaged. Then:
1. Depending on the size and weight, the material is forwarded packed in cardboard
cases on a pallet or in a crate: on receipt open and remove the packing.
2. Read the User and Maintenance Manual and proceed as explained.
The components of the pneumatic exchanger,
including the shaft are made from materials that
are not specifically resistant to chemical products.
If the diaphragm should break, replace these ele-
ments completely if they have come into contact
with the product.
The air-driven motor of the Piusi MA and Piusi MP
pumps is self-lubricating and will not require any
greasing. Therefore avoid using lubricated and
non-dried air.
ascertain that during service no anomalous noise
appears. In that case, stop the pump immediately.
ascertain that the flid at the delivery side does not
contain gas. Therwise stop the pump immediately.
the diaphragms (in contact with the product or the
external ones) are highly subject to wear. Their
duration is strongly affected by the conditions of
use and by chemical and physical stress. Fields tests
carried out on thousands of pumps with a head val-
ue from 0° to 18° C have shown that normal service
life exceeds one hundred million cycles. However,
in places at risk of explosion, the diaphragm must
be disassembled and checked every 5 million cycles
and replaced every 20 million cycles.
periodic controls must be made to ensure that there
is no powder and/or deposits on the external and
internal surfaces of the pump and, if necessary, they
must be cleaned with a damp cloth.
removal of the silencer and the air supply fitting
must be done when free from powder. Before
restarting the pump, ensure that no powder has
entered the pneumatic distributor.
50/208