KAESER KCF 100 Instructions De Montage Et De Service page 22

Séparateur huile-eau
Table des Matières

Publicité

Maintenance • Mantenimiento
Entretien • Manutenção
cartridge
cartucho
catouche
cartucho
22
Weight
Order Ref.
Peso
Nº de referencia
Poids
No de commande
N° de referência
Peso
19.8 lbs
4004442
english
Note:
• It is recommended that an original
cartridge be kept in stock at all times.
• Only use cartridge to ensure opera-
tional reliability. The original cartridges
are identified by their labelling (C) and
the test seal.
• Do not use any other material. Other-
wise the correct functioning of the KCF
(wastewater quality, through-put capac-
ity, service life) cannot be guaranteed.
• Remove plastic bag if present before
cartridge installation!
Procedure
Step 1. Keep the plastic bag of the
new cartridge for wrapping up the old one.
Step 2. Shut off the condensate feed to
the unit.
Step 3. Remove the QWIKPURE lid by
loosening the 4 screws on the lid top.
Step 4. Lift the old cartridge for the main
tank and allow it to drain. Once the cartridge
has drained place it in the plastic bag and
dispose of the unit according to your local
regulations.
Step. 5 Thoroughly clean the internal main
tank with non-abrasive cleaner.
Step. 6 Insert new cartridge slowly and
ensure that the guide pins located on
each side of the cartridge match up to the
container holes
Step 7. Re-install the lid with the 4 screws.
Make sure not to over tighten.
Step 8. MUST BE COMPLETED before
introducing compressed air condensate to
unit. Pour water into the unit from the top
through the pressure relief chamber area.
Step 9. Stop pouring the water (approx. 18
gallons) when it starts to come out at the
water outlet that is located on the side of
the unit.
Step 10. Wait approximately 5 mins so the
cartridge will adsorb some of water & add
additional water to the unit until you see
water coming out of the outlet again. Once
this has been accomplished the unit will
be recharged and ready for full operation.
Step 11. You know can introduce conden-
sate into unit via the multiple inlet adaptor
located on the top lid.
KCF 100

Publicité

Table des Matières
loading