INSTALLATION
SPECIFICATION
9. Specification
9.1
Data table
Electrical details
Power supply
Power consumption
Breaking capacity of the relay
Max. relay breaking capacities
[Max. Spitzenlaststrom]
Max. power across terminal "Netz L" [mains L]
Versions
IP-Rating
Dimensions
Height
Width
Depth
Weights
Weight
Values
Ambient temperature
9.2 Dimensions
WPM-RBS
9.3 Connection example
Control unit WPMW with relay box WPM-RBS
WPM-RBS
230381
1/N/PE ~ 230 V
VA
5
A
2
A
[2 (2)]
A
65
A
10
IP31
mm
211
mm
205
mm
56
kg
0.3
°C
0 - 50
230V
L N
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
1
2
3
1 2 3 4 5 6
L N
L N
L N
Heat 2
Heat 1
1
2
3
WPM II
N
PE
L
C 16 A
WPM-RBS
4
5
6
L N
N
N
Buffer 1
| 11