Device Use; Cleaning And Maintenance - ulsonix AIRCLEAN 10G Manuel D'utilisation

Masquer les pouces Voir aussi pour AIRCLEAN 10G:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
EN
m)
Do not run the device when empty.
n)
It is forbidden to interfere with the structure of
the device in order to change its parameters or
construction.
o)
Keep the device away from sources of fire and heat.
p)
Persons with impaired sense of smell must not use
the device.
q)
Provide enough free space around the device before
turning it on. Do not obstruct the ozone vent holes.
r)
It is strictly forbidden to directly inhale ozone coming
out of the outlet holes of the device. Inhalation of
high concentrations of ozone over a short period
as well as inhalation of low concentrations of ozone
over a long period of time may cause serious risk to
health or life!
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there
is still a slight risk of accident or injury when using
the device. Stay alert and use common sense when
using the device.
3. USE GUIDELINES
Ozone generator produces ozone from surrounding air.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
AIRCLEAN 10G | AIRCLEAN 7G | AIRCLEAN 20G |
AIRCLEAN 15G
2
3
5
1
6
1.
air outlet
2.
control panel buttons:
On/Off – main on/off switch
Auto – auto mode operation
Timer – timer mode operation
Set – access to parameter setting mode
Up – increasing parameter values
Down – decreasing parameter values
3.
display
4.
remote control – description of buttons: same as
control panel buttons
5.
filter
6.
fuse socket
AIRCLEAN 20G-ECO | AIRCLEAN 7G-ECO |
AIRCLEAN 5G-WL
3
5
1
2
4
10
1.
air outlet
2.
operation indicator lamp
3.
operation time selector knob
4.
fuse socket
5.
air filter
AIRCLEAN 7G-WL | AIRCLEAN 10G-WL
4
3
1
5
2
1.
Air outlet
2.
Operation indicator lamp
3.
Operation time selector knob
4.
power cord connection
5.
air filter
AIRCLEAN 10G-ECO
1
2
10
5
3
4
6
9
1.
Handle
2.
A light informing that the device is operating
3.
Ozone control knob
4
4.
"HOLD" button
5.
Time set knob
6.
Air filter cover
7.
Power socket and fuse socket
8.
Air filter
9.
Power cord
10.
ON/OFF button
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40 °C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, fireproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
Disassemble the device and all its components and clean
them before the first use.

3.3. DEVICE USE

Model
Recommended operation duration /
treated airspace [m
P1
10 minute
operation /
20 minute
pause
AIRCLEAN 7G
<100
AIRCLEAN 10G
<140
AIRCLEAN 15G
<210
AIRCLEAN 20G
<280
Model
Recommended operation duration /
treated airspace [m
50
100
AIRCLEAN
10 min
20 min
7G-ECO
AIRCLEAN
4 min
8 min
20G-ECO
AIRCLEAN
20 min
40 min
5G-WL
AIRCLEAN
10 min
20 min
7
7G-WL
AIRCLEAN
8 min
16 min
10G-WL
Model
Recommended operation duration /
treated airspace [m
8
50m
100m
3
AIRCLEAN
8 min
16 min 24 min
10G-ECO
NOTE! Do not exceed the "Recommended operation
duration" as indicated in the above tables. Max. continuous
working time and break time for the ozone generators is:
12 hours of work / 12 hours of break.
NOTE! The device operator takes responsibility for safety
measures and operation of the device.
AIRCLEAN 10G | AIRCLEAN 7G | AIRCLEAN 20G |
AIRCLEAN 15G
Continuous
operation
treatment with ON/Off button. The display will show
"HOLD ON". The device will operate continuously.
Timer mode operation: activate the device with
„Timer" button. The display will show "TIMER OFF
UNTIL" as well as time in hours and minutes until
deactivation of the device. The time can be freely
adjusted in the range between 5 minutes and 24
hours. Timer off modification: upon activating the
device with „Timer" button press "Set" button. Preset
time will start blinking, use "Up"/ "Down" buttons
to set the desired time after which the device is
to deactivate and then press "Set" again – the
modification will be stored in the device and the
device will activate.
Auto mode operation: turn the device on with "Auto"
button, the display will show "ON" / device operation
time and program reference number P1, P2 or P3
(switch between programs by pushing the "Auto"
button in sequence). The device is delivered with
three default programs:
11
EN
► P1: 10 minute operation / 20 minute pause / 5
rounds,
► P2: 20 minute operation / 20 minute pause / 5
] in "Auto" mode
3
rounds,
P2
P3
► P3: 40 minute operation / 20 minute pause / 5
rounds.
20 minute
40 minute
Operation times / pause and number of rounds
operation /
operation /
can be freely modified in each of these programs.
20 minute
20 minute
Modification of operation time, pause and number
pause
pause
of rounds: Operation times / pause and number
100–150
150–200
of rounds can be freely modified in each of these
140–210
210–280
programs. To do this press the "Set" button while in
the program which you wish to modify (P1, P2 or P3).
210–315
315–420
Starting with P1, press "Set" to move to operation
280–420
420–560
time setting, the display will show "Set Pro. ON" as
well as blinking operation time setting – change it
to your desired value using "Up"/"Down" buttons.
]
3
Press "Set" to move to pause time setting, the
150
200
300
display will show "Set Pro. OFF" as well as blinking
pause time setting – change it to your desired value
30 min
40 min
60 min
using "Up"/"Down" buttons. Press "Set" to move to
number of rounds setting. The display will show "Set
12 min
15 min
25 min
Pro. ON OFF" as well as blinking number of rounds.
Use "Up"/"Down" buttons to set your desired value
and press "Set" to move to modification of program
60 min
80 min 100 min
2 (P2). Use the same procedure for the remaining
programmes. To exit programme modifications,
30 min
40 min
60 min
press the "Set" button and hold it until the devices
moves to the first value of previously modified
24 min
32 min
48 min
programme – the device will be activated in auto
mode with programme preset operation and pause
time values as well as preset number of rounds.
]
AIRCLEAN 20G-ECO | AIRCLEAN 5G-WL |
3
AIRCLEAN 7G-ECO | AIRCLEAN 7G-WL |
150m
200m
300m
3
3
3
3
AIRCLEAN 10G-WL
32 min
48 min
Use the operation time selector knob to set the
desired duration of ozonetreatment.
In "HOLD" mode the device will operate continuously.
AIRCLEAN 10G-ECO
Turn the device on using the ON/OFF button located
on the rear panel
Set the desired ozonisation time value using the
ozonisation set knob.
To start continuous operation, turn the time set knob
counter clockwise as far as it will go and press the
"HOLD" button.
mode:
activate
ozone
Use the ozone control knob to set the ozone level.
The available range is 0-10000 mg/h.
NOTE! Upon completion of treatment ventilate the room
for 15 to 30 minutes. Do not enter the room for at least
2 hours after completion of the ozone treatment. PLEASE
NOTE! Use the device only in empty rooms! Ozone is an
irritant gas, it may cause damage to biological membranes
through radical reactions with their constituents. If the
characteristic ozone smell is still present in the room which
was treated with ozone, first make sure that the device is
switched off then leave the room and/or ventilate it.

3.4. CLEANING AND MAINTENANCE

a)
Always unplug the device before cleaning it.
b)
Use only non-corrosive cleaners to clean the surface.
c)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
d)
Do not spray the device with a water jet or submerge
it in water.

Publicité

Table des Matières
loading