Connection of feedback system
Resolver
Contact
Name
B1
+ Ref
B2
- Ref
B3
Not assigned
B4
+COS
B5
-COS
B6
+SIN
B7
-SIN
B8
Not assigned
Incremental encoder / sin/cos absolute value encoder with Hiperface
Contact
Designation
B1
+ U
B2
GND
B3
A / + COS
B4
A / Ref cos
B5
B / + SIN
B6
B / Ref sin
B7
Z / data +
B8
Z / data -
1)
B10
Shield - housing
1) The terminal is not assigned if insulation at N-end shield of the motor has been selected!
Note!
Shield signal cable.
ƒ
Connect shield on both sides.
ƒ
Lenze • MA 33.0009 • 3.0
B
Installation
Meaning
Transformer windings (reference
windings)
Stator winding cosine
Stator winding sine
Meaning
Supply +
Mass
Track A / process data channel
Track A inverse / process data channel
Track B / process data channel
Track B inverse / process data channel
Zero track / parameter channel + RS485
Zero track inverse / parameter channel - RS485
Shield - incremental encoder