- low speed if the air humidity is close to or higher than the suitable level.
Press the button (C) to set the desired degree of humidity; each pulse increases by 5%
starting from a minimum of 45% up to a maximum of 75%.
If you set the humidity level with the button (C) you cannot adjust the steam dispensing
speed because the unit adjusts the steam automatically.
To adjust the steam level, press the button (C) to go back to continuous operation mode.
Press the button (D) if you want to ionize the air.
Pressing the TIMER button (E) you can adjust the time when the product should switch off
up to a maximum of 12 hours. When the water is not enough to operate, a red light on the
display indicates the lack of water.
You can use the product with essential oils or balsamic essences. Press on the drawer at
the bottom of the product, remove it and deposit a few drops on the sponge. Close the
drawer by inserting it into the housing again.
Disconnect the plug from the socket and let the appliance cool down well before
cleaning it.
To reduce bacteria and scale residues, empty the water tank every day after use.
In order to clean the appliance, use a soft or slight damp cloth.
Never use abrasives or chemical solvents.
Do not use very wet substances, liquids or cloths to prevent water from Never use alcohol
or chemicals products to clean the appliance.
NEVER IMMERSE THE APPLIANCE INTO THE WATER.
Preferably use cold water up to 40°C pre-boiled.
Clean the transducer and the water tank once a week. Frequently change the water in the
tank.
Take the water out of the tank and dry it if the product is not used for a long time.
To clean the transducer:
-
clean the surface of the transducer with vinegar and wait for 2-5 minutes.
-
Rinse the transducer with clean water. Never use sharp or hard objects to clean the
transducer.
How to clean the bowl:
-
for daily cleaning, rinse with clean water and dry with a soft cloth.
To remove any lime scale or to make a periodic cleaning of the appliance
proceed as follows:
-
pour a solution of water and vinegar (in equal parts) in the bowl and the tank; leave
the solution works for at least 6 hours.
-
Drain and rinse with clean water and dry.
If the product is not used for a long time dry both bowl and tank, remove the filter (located
underneath the product) and dry it completely; wrap it and store in a dry place.
Maintenance
8 / 28