Features; Function Check; Care And Cleaning - geo-FENNEL FHM 10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data
Measuring range timber
Accuracy timber
Measuring range construction material
Accuracy construction material
Power supply
Dimensions
Weight
*adjusted to european timber at 20°C

FEATURES

• Measuring principle electrical resistance
• Length of electrodes 8mm Impact-proof housing
• Automatic shut-off
• Protection cover with integrated function and battery check
• Replaceable electrodes

FUNCTION CHECK

Connect electrodes with T contacts of the protective cap: „O-----T-----O" .
Display timber
Display construction material
If those values are not displayed instrument should be sent for service.

CARE AND CLEANING

Please handle measuring instruments with care.
Clean with soft cloth only after any use. If necessary damp cloth with some water.
If instrument is wet clean and dry it carefully. Pack it up only if it is perfectly dry.
Transport in original container / case only.
Change of electrodes:
Unscrew all 5 screws on the back of the instrument and remove housing lid. Unscrew all 5 screws on the
electronic plate and replace the electrodes. Close instrument again.
27 % ±2 %
1,25 % ±0,1 %
6 - 44 %
± 1 %*
0,2 - 2 %
± 0,05 %
3 x Cr2032 batteries
130 x 40 x 25 mm
102 g
EN
C
D
E
7

Hide quick links:

Publicité

Table des Matières
loading