GB
oPERAtING INStRuCtIoNS
PLEASE READ THE FOLLOWING OPERATING
INSTRUCTION BEFORE CONNECTING THE UNIT
TO A SUITABLE POWER SUPPLY!
Mobile dehumidifiers are suitable for the home
or workplace . They improve the indoor air con-
ditions and contribute to a healthier, more com-
fortable environment . The dehumidifier reduces
both mould growth and the relative humidity in
rooms, which helps combat mites .
GENERAL INFoRMAtIoN ABout
DEHuMIDIFIERS:
For the following reasons, you will only see water
in the top water tank approx . 8 hours after swit-
ching on the dehumidifier:
The integrated hygrometer needs some time
to measure the relative humidity in the room .
The drainage pipe for continous operation
has to fill with water first (automatically) be-
fore the water starts to collect in the water
tank .
The dehumidifier is suitable for use in rooms with
a maximum of 75 m² . The capacity depends on
the room temperature and the relative humidi-
ty . The dehumidifier is most efficient when the-
re is a combination of high room temperature
and humidity .
Full tank indicator
Operation indicator
Defrost indicator
Temperature
Room humidity
Fan operating
Humidity
setting
16
A relative humidity of approx . 50 % and below
is recommended .
CAutIoN:
After unpacking the unit, please let it rest for
at least 2 hours before switching on.
After transport, the cooling circuit in the air de-
humidifier needs some time to be ready for use .
1. turning the dehumidifier oN:
Ensure that the top water tank is properly at-
tached .
Connect the unit to a suitable power supply
socket and switch on using the "EIN / AuS"-
button (on / off) . The current room tem-
perature and air humidity are shown in the
electronics display . The required air humidity
is set to 00% . This is also the setting for conti-
nued dehumidification (fig. 1) .
then:
Press "EIN / AuS" (on / off) once:
The required air humidity is set to 30 % .
Press "EIN / AuS" (on / off) twice:
The required air humidity is set to 35 % .
Press "EIN / AuS" (on / off) three times:
The required air humidity is set to 40 % .
TANK VOLL
Auto defrosting
BETRIEB
ABTAUEN
Water tank full
30.0 °C
T
Mode /
%RH
80.0
Power switch
F
% RH
60
ON / OFF
EIN/AUS
Press "EIN / AuS" (on / off) four times:
The required air humidity is set to 45 % .
Press "EIN / AuS" (on / off) five times:
The required air humidity is set to 50 % .
Press "EIN / AuS" (on / off) six times:
The required air humidity is set to 55 % .
Press "EIN / AuS" (on / off) eleven times:
The required air humidity is set to 80 % .
If you press "EIN / AuS" (on / off) again, the
process will start again at 00 %.
The unit will turn itself off when the moisture
in the air reaches the selected level .
The unit will automatically turn itself on when
the moisture in the air rises above this level .
If the unit is turned off during operation, it
should be left off for 3 minutes before being
turned on again .
If the unit does not operate, check whether
the top tank is correctly located in the unit
and that the power socket is switched on .
When the top water tank is full and the RED
indicator lights, empty the top tank as descri-
bed in point 3 . The dehumidifier will auto-
matically resume functioning once the empty
water tank has been correctly reinserted .
the dehumidifier is designed to provide an
optimum operating performance between
15° and 35°C.
when used below 15°C, the rate of water ex-
traction will typically be reduced. this may
lead to little or no water being collected in
the unit's water tanks.
2. turning the dehumidifier oFF:
To turn the unit off, press and hold down the
"EIN / AUS" (on / off) button for a few seconds .
If the unit is not to be used for a long period,
unplug it from the power supply and drain
the primary tank as described in point 4 .
(fig. 1)
3. Full tank and top tank removal:
In the "Stand-Alone"-mode, the unit dehumi-
difies the air, and the moisture will be colle-
cted in the integrated water tank . When the
water tank is full, the red indicator on the con-
trol panel will light up, the unit will provide
an acoustic signal to indicate that the tank is
full, and it will stop automatically . When this
•
happens, the top water tank must be remo-
•
ved and emptied . The dehumidifier will auto-
•
matically resume functioning once the empty
water tank has been correctly reinserted .
Please follow the following steps when emp-
tying the top water tank .
a) Slide the lock switch to the RELEASE (fig. 2)
position and ROTATE the handle in the direc-
tion indicated by the arrow to the UNLOCK
position (fig. 3) .
The tank is now in UNLOCK position . Remove
and empty the tank (fig. 4) .
GB
RELEASE
(fig. 2)
ROTATE
(fig. 3)
PULL
(fig. 4)
17